{"created":"2023-05-15T12:31:05.268321+00:00","id":652,"links":{},"metadata":{"_buckets":{"deposit":"c493d50f-86cc-4ecb-9a30-72b7068ec0b6"},"_deposit":{"created_by":6,"id":"652","owners":[6],"pid":{"revision_id":0,"type":"depid","value":"652"},"status":"published"},"_oai":{"id":"oai:fit.repo.nii.ac.jp:00000652","sets":["256:257:360"]},"author_link":["3073","3074","3133"],"item_3_alternative_title_23":{"attribute_name":"タイトル(ヨミ)","attribute_value_mlt":[{"subitem_alternative_title":"スイチョク ジカイカ ニオケル チョウデンドウ ヒライタ チュウ ノ シャヘイ デンリュウ ゼンセン"}]},"item_3_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2002-03-15","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"2","bibliographicPageEnd":"204","bibliographicPageStart":"201","bibliographicVolumeNumber":"34","bibliographic_titles":[{"bibliographic_title":"福岡工業大学研究論集"},{"bibliographic_title":"RESEARCH BULLETIN OF FUKUOKA INSTITUTE OF TECHNOLOGY","bibliographic_titleLang":"en"}]}]},"item_3_description_17":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_3_description_47":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"subitem_description":"論文(Article)","subitem_description_type":"Other"}]},"item_3_description_5":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"When uniform magnetic field is applied perpendicularly to flat surfaces of a superconducting plate, currents are induced in the plate ends and surfaces, so as to shield its interior region from flux penetration. Forms of flux front and also current front are not simple, and difficult to be determined precisely. In order to clear the relation between the external magnetic field and the position of the cur­rent front, magnetic shielding conditions are expressed by using uniform current distribution for a hex­agonal form of the current front having two parameters, which are determined from two shielding con­ditions, one is vanishing of field at the center, the other is the second derivative of the field variation set to zero. Using analytical expressions corresponding to shielding conditions, we get reasonable re­sults for the field dependence of the front position, and the field distribution on the center axis of the plate. It can be noted that surface currents have remarkable contribution to internal shielding effect. ","subitem_description_type":"Other"}]},"item_3_full_name_2":{"attribute_name":"著者(ヨミ)","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"3074","nameIdentifierScheme":"WEKO"}],"names":[{"name":"ノダ, ミノル"}]}]},"item_3_full_name_3":{"attribute_name":"別言語の著者","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"3133","nameIdentifierScheme":"WEKO"}],"names":[{"name":"NODA, Minoru "}]}]},"item_3_publisher_37":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"福岡工業大学"}]},"item_3_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"02876620","subitem_source_identifier_type":"ISSN"}]},"item_3_text_38":{"attribute_name":"出版者(ヨミ)","attribute_value_mlt":[{"subitem_text_value":"フクオカ コウギョウ ダイガク"}]},"item_3_text_39":{"attribute_name":"別言語の出版者","attribute_value_mlt":[{"subitem_text_value":"Fukuoka Institute of Technology"}]},"item_3_text_48":{"attribute_name":"資源タイプ・ローカル","attribute_value_mlt":[{"subitem_text_value":"紀要論文"}]},"item_3_text_49":{"attribute_name":"資源タイプ・NII","attribute_value_mlt":[{"subitem_text_value":"Departmental Bulletin Paper"}]},"item_3_text_50":{"attribute_name":"資源タイプ・DCMI","attribute_value_mlt":[{"subitem_text_value":"text"}]},"item_3_text_51":{"attribute_name":"資源タイプ・ローカル表示コード","attribute_value_mlt":[{"subitem_text_value":"02"}]},"item_3_version_type_19":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"野田, 稔"}],"nameIdentifiers":[{"nameIdentifier":"3073","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_access","displaytype":"detail","filename":"34(2)-201.pdf","filesize":[{"value":"269.0 kB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"url":"https://fit.repo.nii.ac.jp/record/652/files/34(2)-201.pdf"},"version_id":"1eef4803-60a2-416b-879a-22f05f8b4897"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"superconducting plate","subitem_subject_scheme":"Other"},{"subitem_subject":"perpendicular field","subitem_subject_scheme":"Other"},{"subitem_subject":"shielding region","subitem_subject_scheme":"Other"},{"subitem_subject":"hexagonal form of current front","subitem_subject_scheme":"Other"},{"subitem_subject":"shielding conditions","subitem_subject_scheme":"Other"},{"subitem_subject":"field distribution","subitem_subject_scheme":"Other"},{"subitem_subject":"superconducting plate","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"perpendicular field","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"shielding region","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"hexagonal form of current front","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"shielding conditions","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"field distribution","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"垂直磁界下における超伝導平板中の遮蔽電流前線","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"垂直磁界下における超伝導平板中の遮蔽電流前線"},{"subitem_title":"Shielding Current Front in a Superconducting Plate under a Perpendicular Magnetic Field","subitem_title_language":"en"}]},"item_type_id":"3","owner":"6","path":["360"],"pubdate":{"attribute_name":"公開日","attribute_value":"2021-02-08"},"publish_date":"2021-02-08","publish_status":"0","recid":"652","relation_version_is_last":true,"title":["垂直磁界下における超伝導平板中の遮蔽電流前線"],"weko_creator_id":"6","weko_shared_id":-1},"updated":"2023-05-15T13:14:46.329895+00:00"}