{"created":"2023-05-15T12:30:59.676784+00:00","id":558,"links":{},"metadata":{"_buckets":{"deposit":"20fe805e-1163-44b7-8a6d-fd4a69a8a6b1"},"_deposit":{"created_by":2,"id":"558","owners":[2],"pid":{"revision_id":0,"type":"depid","value":"558"},"status":"published"},"_oai":{"id":"oai:fit.repo.nii.ac.jp:00000558","sets":["256:305:316"]},"author_link":["2709","2708","2707"],"item_3_alternative_title_23":{"attribute_name":"タイトル(ヨミ)","attribute_value_mlt":[{"subitem_alternative_title":"ケッカン コウヤクジュツ シエン デバイス ノ サイテキ セッケイ ノ タメノ スウチ カイセキ モデル ノ コウチク"}]},"item_3_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2020-04-15","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"48","bibliographicPageStart":"45","bibliographicVolumeNumber":"2","bibliographic_titles":[{"bibliographic_title":"福岡工業大学総合研究機構研究所所報"}]}]},"item_3_description_17":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_3_description_47":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"subitem_description":"論文(Article)","subitem_description_type":"Other"}]},"item_3_description_5":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"Congenital heart disease such as Ventricular septal defect (VSD), Hypoplastic left heart syndrome (HLHS) and Single Ventricle (SV) have malformations and dysfunctions in the cardiovascular system. In particular, HLHS and SV have a high risk of death due to severe symptoms such as breathing disorder, hyperhidrosis, suckling disorder and cyanosis after birth. Therefore, surgical treatment is immediately considered. To reduce pulmonary vascular resistance, BT shunt or bilateral pulmonary artery banding is performed after birth. In this procedure, a tape of a vascular graft made of ePTFE is wrapped around a blood vessel to control blood flow toward the lungs. In this study, the ultra-small crip with automatic adjustment of banding diameter by wireless communication for blood vessel banding is considered. In this paper, a numerical analysis model of blood vessel and a tape of a vascular graft for blood vessel banding using Finite Element Method is investigated.","subitem_description_type":"Other"}]},"item_3_full_name_2":{"attribute_name":"著者(ヨミ)","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"2708","nameIdentifierScheme":"WEKO"}],"names":[{"name":"トモダ, アキノリ"}]}]},"item_3_full_name_3":{"attribute_name":"別言語の著者","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"2709","nameIdentifierScheme":"WEKO"}],"names":[{"name":"TOMODA, Akinori"}]}]},"item_3_publisher_37":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"福岡工業大学総合研究機構"}]},"item_3_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"24345725","subitem_source_identifier_type":"ISSN"}]},"item_3_text_18":{"attribute_name":"形態","attribute_value_mlt":[{"subitem_text_value":"1438342 bytes"}]},"item_3_text_38":{"attribute_name":"出版者(ヨミ)","attribute_value_mlt":[{"subitem_text_value":"フクオカ コウギョウ ダイガク ソウゴウ ケンキュウ キコウ"}]},"item_3_text_48":{"attribute_name":"資源タイプ・ローカル","attribute_value_mlt":[{"subitem_text_value":"紀要論文"}]},"item_3_text_49":{"attribute_name":"資源タイプ・NII","attribute_value_mlt":[{"subitem_text_value":"Departmental Bulletin Paper"}]},"item_3_text_50":{"attribute_name":"資源タイプ・DCMI","attribute_value_mlt":[{"subitem_text_value":"text"}]},"item_3_text_51":{"attribute_name":"資源タイプ・ローカル表示コード","attribute_value_mlt":[{"subitem_text_value":"02"}]},"item_3_text_79":{"attribute_name":"コメント","attribute_value_mlt":[{"subitem_text_value":"エレクトロニクス研究所(Electronics Research Laboratory)"}]},"item_3_version_type_19":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"鞆田, 顕章"}],"nameIdentifiers":[{"nameIdentifier":"2707","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-09-14"}],"displaytype":"detail","filename":"11478-1529_p45.pdf","filesize":[{"value":"1.4 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"11478-1529_p45.pdf","url":"https://fit.repo.nii.ac.jp/record/558/files/11478-1529_p45.pdf"},"version_id":"efca47e8-9f77-4998-b88f-8cacc139e50b"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"Congenital Heart Disease","subitem_subject_scheme":"Other"},{"subitem_subject":"Finite Element Method","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"血管絞扼術支援デバイスの最適設計のための数値解析モデルの構築","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"血管絞扼術支援デバイスの最適設計のための数値解析モデルの構築"},{"subitem_title":"Development of Numerical Analysis Model for Optimal Design of Support Device of Blood Vessel Banding","subitem_title_language":"en"}]},"item_type_id":"3","owner":"2","path":["316"],"pubdate":{"attribute_name":"公開日","attribute_value":"2020-04-27"},"publish_date":"2020-04-27","publish_status":"0","recid":"558","relation_version_is_last":true,"title":["血管絞扼術支援デバイスの最適設計のための数値解析モデルの構築"],"weko_creator_id":"2","weko_shared_id":2},"updated":"2023-05-15T12:46:26.180828+00:00"}