{"created":"2023-05-15T12:30:55.362391+00:00","id":494,"links":{},"metadata":{"_buckets":{"deposit":"9f71a95e-4597-431d-84d8-235b9fc89bc8"},"_deposit":{"created_by":2,"id":"494","owners":[2],"pid":{"revision_id":0,"type":"depid","value":"494"},"status":"published"},"_oai":{"id":"oai:fit.repo.nii.ac.jp:00000494","sets":["256:305:306"]},"author_link":["2376","2366","2379","2378","2372","2373","2370","2367","2374","2371","2369","2375","2377","2380","2368"],"item_3_alternative_title_23":{"attribute_name":"タイトル(ヨミ)","attribute_value_mlt":[{"subitem_alternative_title":"ユビ ソウチャクガタ ヘルス スクリーニング システム カイハツ ケンキュウ - ムオン ムシンドウ デ ドウサ スル ピエゾポンプ オ モチイタ ケツアツ ケイソク ニ ツイテ ケントウ -"}]},"item_3_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2018-12","bibliographicIssueDateType":"Issued"},"bibliographicPageEnd":"107","bibliographicPageStart":"103","bibliographicVolumeNumber":"1","bibliographic_titles":[{"bibliographic_title":"福岡工業大学総合研究機構研究所所報"}]}]},"item_3_description_17":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_3_description_47":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"subitem_description":"論文(Article)","subitem_description_type":"Other"}]},"item_3_description_5":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"The piezoelectric air pump is a thin, compact, real silent, non-vibration, and lightweight. In this study, we developed the blood pressure (BP) monitoring system, based on the finger volume-oscillometric method, using the piezoelectric air pump. Firstly, Pumping characteristics were experimentally investigated. Secondly, the simultaneous BP measurement was performed for one healthy male (age: 22 years old) using the electronic sphygmomanometer and the prototype system. A load pressure over 200mmHg for BP measurement were achieved with an applied voltage of 15 Vpp and a driving frequency of 23.8 kHz ~ 24.2 kHz. The 4.989 mmHg/s pressurizing speed was controllable by the pulse frequency and delay time. Mean blood pressure and systolic blood pressure were achievable in the finger photoplethysmogram with the cuff. Future work will focus on improvement of the control method for the linear load pressure increasing and the calibration pressure sensor for the high accuracy BP measurement. In conclusion, these findings suggest that it is possible to measure BP with real silent and non-vibration using a piezoelectric air pump in the finger.","subitem_description_type":"Other"}]},"item_3_full_name_2":{"attribute_name":"著者(ヨミ)","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"2371","nameIdentifierScheme":"WEKO"}],"names":[{"name":"フクモト, ユウト"}]},{"nameIdentifiers":[{"nameIdentifier":"2372","nameIdentifierScheme":"WEKO"}],"names":[{"name":"リ, ジヒョン"}]},{"nameIdentifiers":[{"nameIdentifier":"2373","nameIdentifierScheme":"WEKO"}],"names":[{"name":"クサバ, シホリ"}]},{"nameIdentifiers":[{"nameIdentifier":"2374","nameIdentifierScheme":"WEKO"}],"names":[{"name":"ハラダ, アツヒロ"}]},{"nameIdentifiers":[{"nameIdentifier":"2375","nameIdentifierScheme":"WEKO"}],"names":[{"name":"ヤマコシ, タケヒロ"}]}]},"item_3_full_name_3":{"attribute_name":"別言語の著者","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"2376","nameIdentifierScheme":"WEKO"}],"names":[{"name":"FUKUMOTO, Yuto"}]},{"nameIdentifiers":[{"nameIdentifier":"2377","nameIdentifierScheme":"WEKO"}],"names":[{"name":"LEE, Jihyoung"}]},{"nameIdentifiers":[{"nameIdentifier":"2378","nameIdentifierScheme":"WEKO"}],"names":[{"name":"KUSABA, Shihori"}]},{"nameIdentifiers":[{"nameIdentifier":"2379","nameIdentifierScheme":"WEKO"}],"names":[{"name":"HARADA, Atsuhiro"}]},{"nameIdentifiers":[{"nameIdentifier":"2380","nameIdentifierScheme":"WEKO"}],"names":[{"name":"YAMAKOSHI, Takehiro"}]}]},"item_3_publisher_37":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"福岡工業大学総合研究機構"}]},"item_3_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"24345725","subitem_source_identifier_type":"ISSN"}]},"item_3_text_18":{"attribute_name":"形態","attribute_value_mlt":[{"subitem_text_value":"1143449 bytes"}]},"item_3_text_38":{"attribute_name":"出版者(ヨミ)","attribute_value_mlt":[{"subitem_text_value":"フクオカ コウギョウ ダイガク ソウゴウ ケンキュウ キコウ"}]},"item_3_text_48":{"attribute_name":"資源タイプ・ローカル","attribute_value_mlt":[{"subitem_text_value":"紀要論文"}]},"item_3_text_49":{"attribute_name":"資源タイプ・NII","attribute_value_mlt":[{"subitem_text_value":"Departmental Bulletin Paper"}]},"item_3_text_50":{"attribute_name":"資源タイプ・DCMI","attribute_value_mlt":[{"subitem_text_value":"text"}]},"item_3_text_51":{"attribute_name":"資源タイプ・ローカル表示コード","attribute_value_mlt":[{"subitem_text_value":"02"}]},"item_3_text_79":{"attribute_name":"コメント","attribute_value_mlt":[{"subitem_text_value":"情報科学研究所(Computer Science Laboratory)"}]},"item_3_version_type_19":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"福本, 悠斗"}],"nameIdentifiers":[{"nameIdentifier":"2366","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"李, 知炯"}],"nameIdentifiers":[{"nameIdentifier":"2367","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"草場, 志帆里"}],"nameIdentifiers":[{"nameIdentifier":"2368","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"原田, 敦広"}],"nameIdentifiers":[{"nameIdentifier":"2369","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"山越, 健弘"}],"nameIdentifiers":[{"nameIdentifier":"2370","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-09-14"}],"displaytype":"detail","filename":"11478-1245_p103.pdf","filesize":[{"value":"1.1 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"11478-1245_p103.pdf","url":"https://fit.repo.nii.ac.jp/record/494/files/11478-1245_p103.pdf"},"version_id":"c6c49f5c-1dc9-43b1-98f6-c8fd280bf9c6"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"piezoelectric air pump","subitem_subject_scheme":"Other"},{"subitem_subject":"health screening","subitem_subject_scheme":"Other"},{"subitem_subject":"blood pressure","subitem_subject_scheme":"Other"},{"subitem_subject":"finger photo-photoplethysmogram","subitem_subject_scheme":"Other"},{"subitem_subject":"volume-oscillometric method","subitem_subject_scheme":"Other"},{"subitem_subject":"piezoelectric air pump","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"health screening","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"blood pressure","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"finger photo-photoplethysmogram","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"volume-oscillometric method","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"指装着型ヘルススクリーニングシステム開発研究-無音・無振動で動作するピエゾポンプを用いた血圧計測について検討-","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"指装着型ヘルススクリーニングシステム開発研究-無音・無振動で動作するピエゾポンプを用いた血圧計測について検討-"},{"subitem_title":"Development of the Finger-type Wearable Health Screening System - A Study on Measurement of Blood Pressure Using the Real Silent and Non-vibration Running Piezoelectric Air Pump -","subitem_title_language":"en"}]},"item_type_id":"3","owner":"2","path":["306"],"pubdate":{"attribute_name":"公開日","attribute_value":"2019-05-17"},"publish_date":"2019-05-17","publish_status":"0","recid":"494","relation_version_is_last":true,"title":["指装着型ヘルススクリーニングシステム開発研究-無音・無振動で動作するピエゾポンプを用いた血圧計測について検討-"],"weko_creator_id":"2","weko_shared_id":2},"updated":"2023-05-15T12:48:08.203420+00:00"}