{"created":"2023-05-15T12:30:49.741387+00:00","id":401,"links":{},"metadata":{"_buckets":{"deposit":"c8702b5b-e0eb-4c2c-bd7c-343bc03a95ed"},"_deposit":{"created_by":6,"id":"401","owners":[6],"pid":{"revision_id":0,"type":"depid","value":"401"},"status":"published"},"_oai":{"id":"oai:fit.repo.nii.ac.jp:00000401","sets":["256:257:278"]},"author_link":["1809","1812","1811","1810","1814","1813","1815","1807","1808"],"item_3_alternative_title_23":{"attribute_name":"タイトル(ヨミ)","attribute_value_mlt":[{"subitem_alternative_title":"デンジコウバン ノ ジキトクセイヒョウカ ノ タメノ カンベン ナ コウセイ ノ ディジタル ソクテイ システム"}]},"item_3_biblio_info_6":{"attribute_name":"書誌情報","attribute_value_mlt":[{"bibliographicIssueDates":{"bibliographicIssueDate":"2006-09-30","bibliographicIssueDateType":"Issued"},"bibliographicIssueNumber":"1","bibliographicPageEnd":"120","bibliographicPageStart":"115","bibliographicVolumeNumber":"39","bibliographic_titles":[{"bibliographic_title":"福岡工業大学研究論集"}]}]},"item_3_description_17":{"attribute_name":"フォーマット","attribute_value_mlt":[{"subitem_description":"application/pdf","subitem_description_type":"Other"}]},"item_3_description_47":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"subitem_description":"論文(Article)","subitem_description_type":"Other"}]},"item_3_description_5":{"attribute_name":"内容記述","attribute_value_mlt":[{"subitem_description":"A practical magnetic measurement system for use in the research of Goss-oriented silicon-iron sheet, which is built compactly based on the interconnection of digitizing oscilloscope with personal computer, is prcsented. In this system, it was intended to expand the frequency range of power loss measurement down to 10 Hz keeping a good accuracy for the purpose of separating the hysteresis loss and eddy current loss, because this is necessary in researching low core loss materials. The point espe­cially paid attention to for this purpose was the phase and amplitude errors of the integrating circuit which is used both for B-coil and H-coil outputs. It was shown that required measuring accuracy can be kept in the frequency range 10-500 Hz by adopting a suitable integrating circuit and by optimizing the circuit parameters.","subitem_description_type":"Other"}]},"item_3_full_name_2":{"attribute_name":"著者(ヨミ)","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"1810","nameIdentifierScheme":"WEKO"}],"names":[{"name":"コイケ, イサオ"}]},{"nameIdentifiers":[{"nameIdentifier":"1811","nameIdentifierScheme":"WEKO"}],"names":[{"name":"サカイ, ヒロキ"}]},{"nameIdentifiers":[{"nameIdentifier":"1812","nameIdentifierScheme":"WEKO"}],"names":[{"name":"ヤマグチ, トシナオ"}]}]},"item_3_full_name_3":{"attribute_name":"別言語の著者","attribute_value_mlt":[{"nameIdentifiers":[{"nameIdentifier":"1813","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Yamaguchi, Toshinao"}]},{"nameIdentifiers":[{"nameIdentifier":"1814","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Koike, Isao"}]},{"nameIdentifiers":[{"nameIdentifier":"1815","nameIdentifierScheme":"WEKO"}],"names":[{"name":"Sakai, Hiraki"}]}]},"item_3_publisher_37":{"attribute_name":"出版者","attribute_value_mlt":[{"subitem_publisher":"福岡工業大学"}]},"item_3_source_id_7":{"attribute_name":"ISSN","attribute_value_mlt":[{"subitem_source_identifier":"02876620","subitem_source_identifier_type":"ISSN"}]},"item_3_source_id_9":{"attribute_name":"書誌レコードID","attribute_value_mlt":[{"subitem_source_identifier":"AN10036974","subitem_source_identifier_type":"NCID"}]},"item_3_text_18":{"attribute_name":"形態","attribute_value_mlt":[{"subitem_text_value":"1037674 bytes"}]},"item_3_text_39":{"attribute_name":"別言語の出版者","attribute_value_mlt":[{"subitem_text_value":"Fukuoka Institute of Technology"}]},"item_3_text_48":{"attribute_name":"資源タイプ・ローカル","attribute_value_mlt":[{"subitem_text_value":"紀要論文"}]},"item_3_text_49":{"attribute_name":"資源タイプ・NII","attribute_value_mlt":[{"subitem_text_value":"Departmental Bulletin Paper"}]},"item_3_text_50":{"attribute_name":"資源タイプ・DCMI","attribute_value_mlt":[{"subitem_text_value":"text"}]},"item_3_text_51":{"attribute_name":"資源タイプ・ローカル表示コード","attribute_value_mlt":[{"subitem_text_value":"02"}]},"item_3_version_type_19":{"attribute_name":"著者版フラグ","attribute_value_mlt":[{"subitem_version_resource":"http://purl.org/coar/version/c_970fb48d4fbd8a85","subitem_version_type":"VoR"}]},"item_creator":{"attribute_name":"著者","attribute_type":"creator","attribute_value_mlt":[{"creatorNames":[{"creatorName":"小池, 勲"}],"nameIdentifiers":[{"nameIdentifier":"1807","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"酒井, 浩樹"}],"nameIdentifiers":[{"nameIdentifier":"1808","nameIdentifierScheme":"WEKO"}]},{"creatorNames":[{"creatorName":"山口, 俊尚"}],"nameIdentifiers":[{"nameIdentifier":"1809","nameIdentifierScheme":"WEKO"}]}]},"item_files":{"attribute_name":"ファイル情報","attribute_type":"file","attribute_value_mlt":[{"accessrole":"open_date","date":[{"dateType":"Available","dateValue":"2020-09-14"}],"displaytype":"detail","filename":"11478-846_115p小池勲.pdf","filesize":[{"value":"1.0 MB"}],"format":"application/pdf","licensetype":"license_note","mimetype":"application/pdf","url":{"label":"11478-846_115p小池勲.pdf","url":"https://fit.repo.nii.ac.jp/record/401/files/11478-846_115p小池勲.pdf"},"version_id":"10b7f6e6-ef79-4307-871e-3309253a5273"}]},"item_keyword":{"attribute_name":"キーワード","attribute_value_mlt":[{"subitem_subject":"silicon-iron sheet","subitem_subject_scheme":"Other"},{"subitem_subject":"core loss","subitem_subject_scheme":"Other"},{"subitem_subject":"core loss separation","subitem_subject_scheme":"Other"},{"subitem_subject":"magnetic measurement","subitem_subject_scheme":"Other"},{"subitem_subject":"integrating circuit","subitem_subject_scheme":"Other"},{"subitem_subject":"silicon-iron sheet","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"core loss","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"core loss separation","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"magnetic measurement","subitem_subject_language":"en","subitem_subject_scheme":"Other"},{"subitem_subject":"integrating circuit","subitem_subject_language":"en","subitem_subject_scheme":"Other"}]},"item_language":{"attribute_name":"言語","attribute_value_mlt":[{"subitem_language":"jpn"}]},"item_resource_type":{"attribute_name":"資源タイプ","attribute_value_mlt":[{"resourcetype":"departmental bulletin paper","resourceuri":"http://purl.org/coar/resource_type/c_6501"}]},"item_title":"電磁鋼板の磁気特性評価のための簡便な構成のディジタル測定システム","item_titles":{"attribute_name":"タイトル","attribute_value_mlt":[{"subitem_title":"電磁鋼板の磁気特性評価のための簡便な構成のディジタル測定システム"},{"subitem_title":"Compact digital measuring system for evaluating magnetic characteristicsof electrical sheet steels","subitem_title_language":"en"}]},"item_type_id":"3","owner":"6","path":["278"],"pubdate":{"attribute_name":"公開日","attribute_value":"2018-10-12"},"publish_date":"2018-10-12","publish_status":"0","recid":"401","relation_version_is_last":true,"title":["電磁鋼板の磁気特性評価のための簡便な構成のディジタル測定システム"],"weko_creator_id":"6","weko_shared_id":-1},"updated":"2023-05-15T12:59:06.666304+00:00"}